- Internal 8 cm fan
- Meets medical safety standards
- Line input fuse protection
- Output overvoltage protection
- Short circuit protection on all outputs
- Total +12 V output up to 34 A
|
Input Voltage |
90 ~ 265 VAC Full Range | |||||
| Input Frequency |
47 ~ 63 Hz | |||||
| Input Current |
8 A (RMS) for 115 VAC 4 A (RMS) for 230 VAC | |||||
| Inrush Current |
100A MAX. for 230 VAC | |||||
|
Overvoltage |
Voltage |
Min. Load | Max. Load |
Ripple & Noise |
||
| +3.3 V | 0.5 A min | 30 A |
50 mV |
|||
| +5 V | 0.3 A min | 30 A |
50 mV |
|||
| +12 V1 | 1 A min | 17 A |
120mV |
|||
| +12 V2 | 1 A min | 17 A |
120mV |
|||
| -5 V | 0.3 A | 100mV | ||||
| -12 V |
0.8 A |
120mV | ||||
| +5 V sb |
2 A |
50 mV |
||||
|
|
+3.3 V &+5 V total output not exceed 180 W +3.3 V & +5 V & +12 V total output not exceed 380 W | |||||
|
Over Voltage Protection |
+5 V 5.7 V ~ 6.5 V +3.3 V 3.7 V ~ 4.5 V +12 V 13.3 V ~ 15.6 V | |||||
|
Short Circuit Protection |
+3.3 V, +5 V , +12 V short circuit all the output | |||||
|
Hold Up Time |
20ms min. | |||||
| MTBF (hrs) |
100,000 hours | |||||
|
Operating Temperature |
0 ˚C ~ 50 ˚C | |||||
|
Storage Temperature |
-20 ˚C ~ 80 ˚C | |||||
|
Efficiency |
68 % | |||||
| Dimensions |
140 mm x 150 mm x 86 mm | |||||
| Outline Conector |
20+4PIN ATX x1, 4PIN 12V CPU x1, HDD/CDROM x5, FDD x2, SATA x2, Extra +5V(P10) x1 | |||||
Ordering Information:
ACE-4840APM-RS 400 W AC-DC PS/2 ATX Power Supply, meet Medical standard, with PFC